This is the most common thermal analysis method due to its wide range of information provided. The Linseis high temperature DTA is designed to deliver highest calorimetric sensitivity, short time constants and a condensation free sample chamber. These features guarantee superior resolution, baseline stability over the entire instrument lifetime. Thus providing a indispensable tool for material development, R&D and quality control.
The modular concept of the DSC and DTA systems allows the use of different furnaces with a temperature range from -150 up to 2400°C, different DTA measuring systems as well as many different crucibles. The vacuum tight design enables quantitiative enthalpy determination under cleanest atmosperes as well as under vacuum 10E-5mbar. Additionaly the systems can be coupled to a MS or FTIR.
Specifications
| Temperature range: | -150°C ... 700°C |
| RT - 1000/1600/1750/2000/2400°C | |
| Sensors: | E/K/S/B/W |
| Sensor Types: | DTA |
| Heating rates: | 0.001 K/min ... 50 K/min |
| Cooling rates: | 0.001 K/min ... 50 K/min (temperature dependent) |
| Sensor: | heat flux |
| Atmospheres: | reducing, oxid., inert (static, dynamic) |
| Vacuum: | 10E-5mbar |
| PC Interface: | USB |
Software
All LINSEIS thermo analytical instruments are PC controlled. The individual software modules exclusively run under Microsoft® Windows® operating systems. The complete software consists of 3 modules: temperature control, data acquisition and data evaluation. The 32 bit software incorporates all essential features for measurement preparation, execution, and evaluation of a DTA measurement. Thanks to our specialists and application experts, LINSEIS was able to develop comprehensive easy to understand user friendly application software.
General Features
- Program capable of text editing
- Repetition measurements with minimum parameter input
- Evaluation of current measurement
- Curve comparison up to 32 curves
- Curve subtraction
- Multi-methods analysis (DSC TG, TMA, DIL, etc.)
- Zoom function
- 1. and 2. Derivative
- Complex peak evaluation
- Multipoint calibration for sample temperature
- Multipoint calibration for change of enthalpy
- Cp calibration for heat flow
- Storage and export of evaluations
- Export and import of data ASCII
- Data export to MS Excel
- Signal-steered measuring procedures
- Zoom in function
Accessories
- Different manual, semi-automatic and automatic Gas Control Boxes (with MFC)
- Broad range of crucibles made of (alumina oxide, graphite, tungsten, gold, silver, platinum, etc.)
- Liquid Nitrogen Cooling unit (-150°C)
- Different vacuum and turbo molecular pump are available